Measurement of gaseous media

Notes:
Very well suitable

Well suitable

Suitable

Not suitable
 
Available

Not available
  Suitable to some extent - please contact the Service Center at 1300 365 088 in this case.
  Calorimetric
inline sensors
Calorimetric
immersion sensors
  Product details Product details

Measuring principle

Calorimetric

Calorimetric

Accuracy

Pressure loss

Detection of direction

Quantity meter (totaliser)

Media    

Non-conductive media

Chemical liquids
of low concentration,
e.g. sodium hydroxide solution < 5%

Resistant to    

Temperature fluctuations

Viscosity changes

Air content

Particles

Pressure peaks

Deposits

Vibrations

Installation    

No inlet pipe length required

Calorimetric inline sensors Special features



Measuring principle

Product series

  • SD series

Measuring range

  • 0.2...200l/min

Cross section

  • 1/2"...1 1/2"

Medium temperature

  • -10...100°C

Pressure rating

  • 40 bar

Requirement

  • Inlet and outlet pipe lengths must be taken into account
  • Thermally conductive medium
  • Avoid rapid temperature changes

Industries

  • Automotive industry
  • Robotics and automation
  • Ship automation
  • Food industry

Highlights

  • High measurement accuracy
  • High measurement dynamics
  • Low pressure loss

Process values

  • Measurement of the total quantity/ totaliser
  • Flow
  • Temperature
  • Pressure
  • Device status/ diagnostics

Calorimetric immersion sensors

Special features


Measuring principle

Product series

  • SI, SA and SF series

Nominal diameter

  • Independent of DN

Measuring range

  • Liquid 0.04...3m/s
  • Gas 0.6...100m/s

Accuracy

  • Liquid ± (7% MV + 2% VMR)
  • Gas ± (10% MV + 2% VMR)

Medium temperature

  • -20...90°C

Pressure rating

  • Up to 300 bar

Requirement

  • Inlet and outlet pipe lengths must be taken into account
  • Thermally conductive medium
  • Avoid rapid temperature changes

Industries

  • Automotive industry
  • Robotics and automation
  • Water industry
  • Ship automation
  • Food industry

Highlights

  • Independent of nominal pipe diameters
  • Diverse material selection for components in contact with the medium
  • Easy set-up

Process values

  • Point flow velocity
  • Temperature
  • Device status/ diagnostics
  • Calculated flow

Product platforms -> Flow sensors/ flow meters