Positioner for industrial valves
MVQ301
MVQ3360-XRKG/IO/B-Port/2SV/US
Positioner for industrial valves
MVQ301
MVQ3360-XRKG/IO/B-Port/2SV/US
- Integrated adjustment algorithm with self-optimisation for positioning of industrial valves accurate to a percentage
- Automatic Teach-In function for fast set-up
- Reduced wiring due to direct control of the control valve
- Self-diagnostics regarding wear, blockages or deposits for preventive maintenance
- Individually adjustable RGB LED with flashing mode for easy visual localisation in challenging environments
To ensure the correct functioning of the device, we strongly recommend purchasing one of the complete positioner sets for the initial setup. Click here for an overview.
Product characteristics
Communication interface | IO-Link |
---|---|
Housing | rectangular |
Dimensions [mm] | 95 x 50 x 57 |
Electrical design | PNP |
---|---|
Output function | 2 x normally open |
Application
Operating principle | magnetic |
---|---|
Application | angle of rotation detection absolute; position control |
Electrical data
Protection class | III |
---|---|
Reverse polarity protection | yes |
Max. power-on delay time [ms] | 300 |
Operating voltage [V] | 20...30 DC |
---|---|
Current consumption [mA] | < 410 |
Operating voltage [V] | 20...30 DC |
---|---|
Current consumption [mA] | < 40 |
Outputs
Electrical design | PNP |
---|---|
Output function | 2 x normally open |
Max. current load per output [mA] | 200 |
Short-circuit protection | yes |
Overload protection | yes |
Detection zone
Detection zone [°] | 360 |
---|
Accuracy / deviations
Accuracy [°] | ± 1 |
---|---|
Temperature drift [°/K] | 0,02 |
Repeatability [°] | 0,1 |
Deadband |
|
|
---|---|---|
Resolution [%] | 0,1; (preset value) |
Hysteresis [%] | 0.4...10; (Factory setting: 1 %) |
---|
Open |
|
|
---|---|---|
Closed |
|
Interfaces
Communication interface | IO-Link | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Transmission type | COM2 (38,4 kBaud) | ||||||||||
IO-Link revision | 1.1 | ||||||||||
SDCI standard | IEC 61131-9 CDV | ||||||||||
Profiles |
|
||||||||||
SIO mode | no | ||||||||||
Required master port type | B | ||||||||||
Min. process cycle time [ms] | 6 | ||||||||||
Supported DeviceIDs |
|
Operating conditions
Ambient temperature [°C] | -25...70 |
---|---|
Protection | IP 65; IP 67; (Target puck area dust-protected) |
Tests / approvals
EMC |
|
||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Vibration resistance |
|
||||||||||
Shock resistance |
|
||||||||||
MTTF [years] | 421 | ||||||||||
Embedded software included | yes |
Mechanical data
Weight [g] | 188.8 |
---|---|
Housing | rectangular |
Dimensions [mm] | 95 x 50 x 57 |
Materials | housing, target puck: PA; plug, socket: stainless steel (316L / 1.4404) |
Tightening torque [Nm] | target puck: 1,2; housing: 3,0; housing on plastic mounting plate: 1,5 |
Displays / operating elements
Display |
|
---|
Accessories
Items supplied |
|
---|
Remarks
Pack quantity | 1 pcs. |
---|