Pressure sensors |
- Current system pressure
- Current temperature*
- Switching outputs
- Device status
|
- Set switching output, switching and timer function
- Zero-point calibration
- Key lock provides protection against tampering
- Visual localisation of the sensor via LED flashing
- Display settings (orientation, colour, on/off)
- Overload counter
- Min./max. value memory
- Error diagnostics (device, process, communication)
|
- Hygienic applications
- Hydraulics
- Pneumatics
- Water, wastewater
- Monitoring of highly viscous or abrasive media
|
Pressure sensors with IO-Link |
Flow sensors |
- Current volumetric flow
- Current temperature
- Current flow quantity totaliser*
- Switching outputs
- Device status
|
- Set switching output, switching and timer function
- Simulation*
- Low flow cut-off*
- Damping
- Key lock provides protection against tampering
- Visual localisation of the sensor via LED flashing
- Min./max. value memory
- Display settings (brightness, layout, orientation, colour)
- Error diagnostics (device, process, communication)
|
- Monitoring the flow of water, oil, deionised water, glycol & air
- Energy management/monitoring
- Heat quantity calculation
- Monitoring of cooling water
- Membrane filter monitoring
|
Flow sensors with IO-Link |
Compressed air meters |
- Current volumetric flow
- Current temperature
- Current pressure
- Current flow quantity totaliser*
- Switching outputs
- Device status
|
- Set switching output, switching and timer function
- Simulation
- Low flow cut-off
- Scaling analogue output
- Read & reset consumed quantity
- Zero-point calibration
- Damping
- Min./max. value memory
- Display settings (brightness, layout, orientation, colour, units)
- Visual localisation of the sensor via LED flashing
|
- Energy monitoring
- Leakage monitoring
- Control of energy costs
- Energy management system DIN EN ISO50001
- Consumption measurement of industrial gases (argon, carbon dioxide, nitrogen and air)
- Air gap control / Part seat monitoring
|
Compressed air meter with IO-Link |
Level sensors |
- Current level
- Current temperature*
- Switching outputs
- Device status
|
- Teach operation
- Set switching output, switching and timer function
- Offset tank bottom
- Medium selection
- Key lock provides protection against tampering
- Display settings (brightness, on/off, units)
|
- Continuous monitoring at the tank (hygienic, industrial)
- Level monitoring at the hydraulic power pack
|
Level sensors with IO-Link |
Point level sensors |
- Current value of the damping
- Switching outputs
- Device status
|
- Teach operation
- Set switching output, switching and timer function
|
- Reliable detection with suppression/recognition of deposits and foam
- Check CIP process
- Medium differentiation (foam, liquid, separation layer)
|
Hygienic point level sensors with IO-Link |
Industrial point level sensors with IO-Link |
Capacitive point level sensors |
- Current value of the damping
- Current temperature
- Switching outputs
- Device status
|
- Empty and full teach
- Set switching output, switching and timer function
- Min./max. value memory
- Visual localisation of the sensor via LED flashing
|
- Leakage monitoring
- Overflow prevention
- Inspection in collecting tray (WHG - German Federal Water Act)
|
Capacitive point level sensors with IO-Link |
Conductivity sensors |
- Current conductivity
- Current temperature
- Switching outputs
- Device status
|
- Set switching output, switching and timer function
- Zero-point calibration
- Calibration gain
- Damping
- Simulation
- Operating hours counter per temperature range
- Min./max. value memory
- Visual localisation of the sensor via LED flashing
|
- Water filtration - From municipal water to ultra-pure water
- Condition-based cleaning process instead of time-based cleaning
- Efficient cooling water monitoring
|
Conductivity sensors with IO-Link |
Temperature sensors |
- Current temperature
- Switching outputs
- Device status
|
- Set switching output, switching and timer function
- Zero-point calibration
- Min./max. value memory
- Select LED mode
- Display settings (orientation, colour, on/off, unit)*
- Key lock provides protection against tampering*
|
Temperature measurement of e.g.
- Products in the food industry
- Drives and motors in mechanical engineering
- Cooling circuits in the steel and metal industry
|
Temperature sensors with IO-Link |
Self-monitoring Temperature sensors |
- Current temperature
- Current reference temperature
- Device status
- Calibration check status
|
- Scale the analogue output
- Min./max. value memory
- Store installation date
- Simulation
- Operating hours counter per temperature range
- Visual localisation of the sensor via LED flashing
|
- Temperature measurement
- Self-monitoring
- Reduced calibration intervals
- 5-point calibration report
|
Self-monitoring temperature sensors with IO-Link |
Air humidity sensors |
- Current humidity
- Current temperature
- Device status
|
- Min./max. value memory
- Switch-on processes and general operating hours counter
- Operating hours counter per temperature and humidity range
|
- Monitoring the humidity and temperature of the ambient air, e.g. in control cabinets
- Compressor efficiency in the compressor room
|
Air humidity sensors with IO-Link |
Vibration monitoring |
- Current fatigue (vRms)
- Current impact (aPeak)
- Current friction (aRms)
- Current internal temperature
- Current crest factor
- Switching outputs
- Device status
|
- Set switching output, switching and timer function
- Record raw data for analysis (BLOB)
- Store installation date
- Min./max. value memory
- Set the frequency filter
- Check and start self-test
- Switch-on operations and operating hours
- Real operating hours counter via threshold
|
- Intelligent vibration monitoring
- (Unbalance, alignment, loosening, belts, impact/crash, abrasion, rolling element bearing, cavitation and gearing)
- Monitoring of e.g. pumps, motors, fans
|
Vibration diagnostics with IO-Link |