Application
Design |
only for operation with IO-Link masters AL140x, AL1304 to AL1307 and Siemens PLCs S7-1200 and S7-1500 (except software controller and open controller) |
Application |
I/O modules for field applications |
Electrical data
Operating voltage [V] |
19.2...30.2 DC; (US ; to SELV/PELV) |
Current consumption [mA] |
67; (US) |
Protection class |
III |
Additional voltage supply [V] |
19.2...30.2 DC; (UA) |
Max. current consumption from additional supply [mA] |
34; (UA) |
Actuator supply UA
Max. current load total [A] |
6 |
Current rating per port [A] |
2 |
Inputs / outputs
Total number of inputs and outputs |
12 |
Inputs
Total number of inputs |
8 |
Switching level high [V] |
11...30 |
Switching level low [V] |
-30...5 |
Digital inputs protected against short circuits |
yes |
Outputs
Total number of outputs |
4 |
Short-circuit proof |
yes |
Interfaces
Communication interface |
IO-Link |
Supported DeviceIDs |
Type of operation |
DeviceID |
default |
1312 |
|
IO-Link Device
Transmission type |
COM3 (230,4 kBaud) |
IO-Link revision |
1.1 |
SDCI standard |
IEC 61131-9 |
SIO mode |
no |
Operating conditions
Ambient temperature [°C] |
-25...60 |
Storage temperature [°C] |
-40...85 |
Max. relative air humidity [%] |
75 |
Protection |
IP 65; IP 67 |
Tests / approvals
EMC |
EN 61000-6-2 |
|
EN 61000-4-2 ESD |
6 kV CD / 8 kV AD |
EN 61000-4-3 HF radiated |
10 V/m |
EN 61000-4-4 Burst |
2 kV |
EN 61000-4-5 Surge |
|
EN 61000-4-6 HF conducted |
|
|
Shock resistance |
|
Vibration resistance |
DIN EN 60068-2-64 2009-04 |
|
DIN EN 60068-2-6 2008-10 |
|
|
Safety classification
Mission time TM [h] |
175200 |
Mission time TM (additional indication) |
|
Single channel
Complies with the requirements |
ISO 13849-1 PL d |
IEC 61508 SIL 2 |
IEC 62061 SIL 2 |
|
PFH [1/h] |
1E-08 |
PFD [1/h] |
1E-04 |
Dual channel
Complies with the requirements |
ISO 13849-1 PL e |
IEC 61508 SIL 3 |
IEC 62061 SIL 3 |
|
PFH [1/h] |
1E-09 |
PFD [1/h] |
1E-05 |
Mechanical data
Weight [g] |
408.3 |
Materials |
housing: PA; socket: brass nickel-plated |
Remarks
Remarks |
Safety classification depends on parameterisation and wiring (see operating instructions). |
|
Pack quantity |
1 pcs. |
Electrical connection - Address Plug
X41 |
Connector: M12; coding: A |
Electrical connection - IO-Link
X21 |
Connector: M12; coding: A |
Electrical connection - Power IN
X31 |
Connector: M12; coding: L |
Electrical connection - Safety Inputs
X01...X04 |
Connector: M12; coding: A |
Electrical connection - Safety Outputs
X05...X08 |
Connector: M12; coding: A |