Product characteristics
Number of inputs and outputs Number of digital outputs: 2; Number of analog outputs: 1
Measuring range
7...360 gph 0.1...6 gpm
Process connection threaded connection 3/4" NPT
Application
System gold-plated contacts
Application for industrial applications
Media Liquids; water; glycol solutions; Coolants
Note on media
oil 1 with viscosity: 10 mm²/s (104 °F)
oil 2 with viscosity: 46 mm²/s (104 °F)
Medium temperature [°F] 14...212
Pressure rating [bar] 40
Pressure rating [MPa] 4
MAWP (for applications according to CRN) [bar] 40
Electrical data
Operating voltage [V] 18...30 DC; (to SELV/PELV)
Current consumption [mA] < 50
Protection class III
Reverse polarity protection yes
Power-on delay time [s] < 3
Inputs / outputs
Number of inputs and outputs Number of digital outputs: 2; Number of analog outputs: 1
Outputs
Total number of outputs 2
Output signal switching signal; analog signal; frequency signal; IO-Link; (configurable)
Number of digital outputs 2
Output function normally open / closed; (configurable)
Max. voltage drop switching output DC [V] 2
Permanent current rating of switching output DC [mA] 150; (per output 2 x 200 (...140 °F); 2 x 250 (...104 °F))
Switching cycles (mechanical) 10 million
Number of analog outputs 1
Analog current output [mA] 4...20
Max. load [Ω] 500
Short-circuit protection yes
Overload protection yes
Frequency of the output [Hz] 0...10000
Measuring/setting range
Measuring range
7...360 gph 0.1...6 gpm
Display range
0...432 gph 0...7.2 gpm
Resolution
1 gph 0.05 gpm
Set point SP
2...360 gph 0.05...6 gpm
Reset point rP
0...358 gph 0...5.95 gpm
Frequency end point, FEP
24...360 gph 0.4...6 gpm
In steps of
1 gph 0.05 gpm
Frequency at the end point FRP [Hz] 10...10000
Measuring dynamics 1:50
Temperature monitoring
Measuring range [°F] 14...212
Display range [°F] -26...252
Resolution [°F] 2
Set point SP [°F] 16...212
Reset point rP [°F] 14...210
In steps of [°F] 2
Frequency start point, FSP [°F] 14...172
Frequency end point, FEP [°F] 54...212
Frequency at the end point FRP [Hz] 10...10000
Accuracy / deviations
Flow monitoring
Accuracy (in the measuring range) ± (4 % MW + 1 % MEW); (Q > 0,5 l/min; medium and operating temperature: +71,6 °F ± 4K)
Repeatability ± 1 % MEW
Temperature monitoring
Temperature drift 0,9802 °F / K
Accuracy [K] 3 K (77 °F; Q > 1 l/min)
Reaction times
Flow monitoring
Response time [s] 0.01
Damping process value dAP [s] 0...5
Damping for the analog output dAA [s] 0...5
Temperature monitoring
Dynamic response T05 / T09 [s] T09 = 120 (Q > 1 l/min)
Software / programming
Parameter setting options hysteresis / window; normally open / closed; switching logic; current output; medium selection; damping for the switching output / analog output; display can be rotated and switched off; standard unit of measurement; process value color
Interfaces
Communication interface IO-Link
Transmission type COM2 (38,4 kBaud)
IO-Link revision 1.1
SDCI standard IEC 61131-9 CDV
Profiles Smart Sensor: Process Data Variable; Device Identification
SIO mode yes
Required master port class A
Process data analog 2
Process data binary 2
Min. process cycle time [ms] 5
Supported DeviceIDs
Type of operation DeviceID
default 566
Operating conditions
Ambient temperature [°F] 32...140
Note on ambient temperature
medium temperature < 176 °F
medium temperature < 212 °F: 32...104 °F
Storage temperature [°F] 5...176
Protection IP 65; IP 67
Tests / approvals
EMC
DIN EN 61000-6-2
DIN EN 61000-6-3
Shock resistance
DIN EN 60068-2-27 20 g (11 ms)
Vibration resistance
DIN EN 60068-2-6 5 g (10...2000 Hz)
MTTF [years] 145
UL approval
UL approval number I005
Pressure equipment directive sound engineering practice; can be used for group 2 fluids; group 1 fluids on request
Mechanical data
Weight [g] 691.5
Material stainless steel (1.4404 / 316L); PBT+PC-GF30; PBT-GF20; PC; brass chemically nickel-plated
Materials (wetted parts) stainless steel (1.4401 / 316); stainless steel (1.4404 / 316L); brass (2.0371); brass chemically nickel-plated; PPS; O-ring: FKM
Process connection threaded connection 3/4" NPT
Displays / operating elements
Display
Display unit 3 x LED, green
Switching status 2 x LED, yellow
Measured values alphanumeric display, red/green 4-digit
Programming alphanumeric display, 4-digit
Remarks
Remarks
Use of 200 micron filtration is recommended.
All data refer to water (68 °F).
MW = Measured value
MEW = Final value of the measuring range
Notes Please note the changed housing design!
Pack quantity 1 pcs.
Electrical connection
Connection Connector: 1 x M12; coding: A; Contacts: gold-plated
Diagrams and graphs
Pressure loss
dP Pressure loss
Q volumetric flow quantity