Fail-safe inductive sensor
GM701S
GIMC-4030-US/2OSSD
Fail-safe inductive sensor
GM701S
GIMC-4030-US/2OSSD
- For ensuring machine safety
- Certified to the following standards: EN 60947-5-3, IEC 61508 and ISO 13849
- No special actuator for electronic fail-safe sensors required
- Connection to safety PLC and safe evaluation units
ifm packages all our safety products in cardboard boxes with test seals. Only products packaged this way with unbroken seals are genuine ifm products.
Product characteristics
Electrical design | PNP |
---|---|
Output function | 2 x OSSD (A1 and A2) |
Enable zone [mm] | 10...15 |
Housing | rectangular |
Dimensions [mm] | 40 x 40 x 66 |
Application
System | gold-plated contacts |
---|---|
Type of operation | continuous operation (maintenance-free) |
Safety-related function | safe state when undamped |
Application | Industrial applications |
Electrical data
Operating voltage [V] | 19.2...30 DC |
---|---|
Rated insulation voltage [V] | 30 |
Current consumption [mA] | < 15 |
Protection class | III |
Reverse polarity protection | yes |
Max. power-on delay time [ms] | 5000 |
Outputs
Electrical design | PNP |
---|---|
Output function | 2 x OSSD (A1 and A2) |
Max. voltage drop switching output DC [V] | 2.5; (100 mA) |
Output data | Interface type C class 0 |
Output voltage at 24 V | compatible with EN 61131-2 inputs type 1, 2, 3 |
Short-circuit protection | yes |
Max. capacitive load CL_max [nF] | 20 |
Monitoring range
Enable zone [mm] | 10...15 |
---|---|
Safe switching-off distance s(ar) [mm] | 30 |
Reaction times
Response time to safety request [ms] | 50 |
---|---|
Response time when approaching the enable zone [ms] | 200 |
Risk time (response time for safety-related faults) [ms] | 100 |
Operating conditions
Applications | Class C to EN 60654-1 weatherproof application | |
---|---|---|
Ambient temperature [°C] | -25...70 | |
Note on ambient temperature |
|
|
Ambient temperature [°C] | 10...40 | |
Note on ambient temperature |
|
|
Rate of temperature change [K/min] | 0.5 | |
Max. relative air humidity [%] | briefly: 5...95 %; permanent: 5...70 % | |
Air pressure [kPa] | 80...106 | |
Max. height above sea level [m] | 2000 | |
Ionizing radiation | not permissible | |
Salt spray | no | |
Protection | IP 65; IP 67 |
Tests / approvals
EMC |
|
||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Shock resistance |
|
||||||||||||||||||
Vibration resistance |
|
Safety classification
Complies with the requirements |
|
|||
---|---|---|---|---|
MIssion time TM [h] | ≤ 175200 | |||
Mission time TM (additional indication) |
|
|||
PFH [1/h] | 1E-08 |
Mechanical data
Weight [g] | 342.5 |
---|---|
Housing | rectangular |
Mounting | non-flush mountable |
Dimensions [mm] | 40 x 40 x 66 |
Material | PPE; diecast zinc |
Displays / operating elements
Display |
|
---|
Remarks
Remarks |
|
||
---|---|---|---|
Pack quantity | 1 pcs. |
Electrical connection - plug
Connection | Connector: 1 x M12; coding: A; Contacts: gold-plated |
---|